MICORVAX II & III ERROR CODES FOR THE CPU LEDS DESCRIPTION The diagnostic light display is for Microvax II and III CPU LEDs. Interrupt level #31 is the highest priority, a hardware fault, and is usually fatal. Interrupt levels #16-31 are high level, time critical. Interrupt levels #0-15 are normal. 0 is the lowest priority. Lights on the CPU board. CODE Error Condition 0 Test Complete no lights on last to be run 1 Bootstrap device found 2 Search for bootstrap device 3 Run interrupt test 4 CPU instruction and register tests 5 Run test on Q-22 nap to local memory 6 Run address test on RAM 7 Run data test on RAM 8 Language inquiry or CPU halted (if step passes, get version # on CRT) 9 Identify console A Test video display B Reading KA-630-A IPCR register C Search for RAM required for ROM programs D Run checksum on CPU ROM E Waiting for P OK F Waiting for DC OK all lights on first to be run SEE ALSO Dec hardware manuals.