SUN 3/260 CPU ERROR CODE FOR THE CPU LEDS DESCRIPTION The diagnostic light display if for Sun 3/260 CPUs only. LSB MSB LEDS WHAT THE SYSTEM IS DOING WHAT PART OF THE *=ON 0=OFF (LEDS CYCLING) SYSTEM FAILED (FROZEN) **** **** A reset sets LEDs to this state CPU, BOOT PROM, +5VDC *000 0000 Test 1 checking the boot PROM BOOT PROM 0*00 0000 Test 2 checking the DVMA reg CPU card **00 0000 Test 3 checking the Context reg MMU section of the CPU card 00*0 0000 Test 4 segment map RAM w/r test MMU section of the CPU card *0*0 0000 Test 5 checking segment map RAM MMU section of the CPU card 0**0 0000 Test 6 checking page map RAM MMU section of the CPU card ***0 0000 Test 7 checking memory data path Resident or expansion memory 000* 0000 Test 8 checking bus error detection CPU bus error register (back out all CCAs to find bad board) *00* 0000 Test 9 checking interrupt capabilities CPU card (or lithium battery) 0*0* 0000 Test 10 checking MMU read access CPU card **0* 0000 Test 11 checking MMU write access CPU card 00** 0000 Test 12 writing to an invalid page MMU section of CPU card *0** 0000 Test 13 writing to a protected page MMU section of CPU card 0*** 0000 Test 14 check does not make parity Parity latch on CPU card **** 0000 Test 15 check does make parity Parity latch on CPU card 0000 *000 Test 16 initiates memory test Resident or expansion memory 0000 000* Self test error report CPU or expansion memory card 0000 00*0 Exception class error report CPU, BOOT PROMS 0000 0*00 Self test done, heartbeat Waiting for boot *_*_ *_*_ Walking 1's pattern. UNIX executing successfully If you are running to a standard bit map display at the successful conclusion of these self tests you will see the 'heartbeat' LED flashing. If SunOS successfully boots you will see a 'walking ones' pattern. If you do not have a display on the monitor you either have a bad monitor/cable or an incorrect EEPROM setting at locations 0x16 and 0x1f. SEE ALSO Sun hardware manuals.